| Nominal diameter | 63, 75 and 100 mm | 
| Accuracy | ±1.5 % of full scale | 
| Scale range (kPa, mbar) | -50 ~ 0 to -5 ~ 0 kPa -15 ~ 15 to -2.5 ~ 2.5 kPa
 0 ~ 5 to 0 ~ 50 kPa
 | 
| Working pressure | Steady : 75 % of full scale Over range protection : 130% of full scale
 | 
| Working temperature | Ambient : -20 ~ 60 °C Fluid : Max. 60 °C
 | 
| Temperature effect | Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately ±0.6 % per 10 ℃ of full scale
 | 
| Pressure connection | Nickel plated brass 316SS, only available with 63 mm "F" type
 | 
| Element | Beryllium copper | 
| Case | Nickel plated steel Stainless steel (304SS), only available with 63 mm "F" and "J" type
 | 
| Cover | Nickel plated steel Stainless steel (304SS), only available with 63 mm "F" and "J" type
 | 
| Window | Glass Polycarbonate | 
| Movement | Brass | 
| Dial | White aluminium with black graduations | 
| Pointer | Black painted aluminium alloy | 
| Process connection | 63 mm : ⅛", ¼" PT, NPT and PF 75 mm : ¼", ⅜" PT, NPT and PF
 100 mm : ⅜", ½" PT, NPT and PF
 | 
| Manufacturer |  |