| Accuracy | ±1.0 % of full scale
±1.6 % of full scale
|
| Scale range (MPa, kPa, bar) | 0 ~ 4 kPa, 6 kPa, 10 kPa (P671 model)
0 ~ 25 kPa to 0 ~ 0.25 MPa (P672 model)
0 ~ 0.4 MPa to 0 ~ 2.0 MPa (P673 model)
|
| Static pressure | P671 : Max. 4 MPa
P672 and P673 : Max. 10 MPa
|
| Working temperature | Ambient : -20 ~ 65 °C
Fluid : Max. 100 °C
|
| Degree of protection | EN60529/IEC529/IP67
|
| Temperature effect | Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately
±0.5 % per 10 ℃ of full scale
|
| Pressure connection | Stainless steel (316L SS), Monel and Hastelloy-C
|
| Element | Bellows
Stainless steel (316L SS), Monel and Hastelloy-C
|
| Case and cover | Stainless steel (304SS)
|
| Window | Safety glass
|
| Dial | White aluminium with black graduations
|
| Filling liquid for differential cell | Silicone oil
|
| Pointer | Black painted aluminium alloy (Zero adjustable)
|
| Process connection | ¼" NPT(F)
½" NPT(F) at 3-way and 5-way manifold valve
|
| Standard accessories | Mounting bracket for 2" pipe
mounting with silver gray finished steel
|
| Option | ■ Remote seal - Not available with less than 40 kPa of differential pressure range
■ Mounting bracket with 316SS for 2" pipe
■ 3-way and 5-way manifold valve
■ 3-way and 5-way manifold valve (Monel)
■ Accuracy ±0.5 % of full scale
|
| Manufacturer |  |