| Nominal diameter | 125 mm | 
| Accuracy | Indicator : ±1.0 % of full sacle Switch setting : ±3 % of full sacle
 | 
| Repeatability | ±1.0 % of adjustable range | 
| djustable range (MPa, kPa, bar) | -0.1 ~ 0 to -0.1 ~ 2 MPa 0 ~ 0.1 to 0 ~ 40 MPa
 | 
| Switch differential | Fixed, less than 6 ~15 % of full sacle | 
| Working temperature | Ambient : -20 ~ 65 °C Fluid : Max. 100 °C
 | 
| Temperature effect | Accuracy at temperature above and below the reference temperature (20 °C) will be effected by approximately ±0.4 % per 10 °C of full scale
 | 
| Element | C type bourdon tube, Helical type bourdon tube | 
| Case and cover | ALDC12.1 Silver gray painted aluminium
 | 
| Setpoint adjustment | External | 
| Contact | Micro contact type One SPDT or Two SPDT
 | 
| Contact rating | SPDT contact rating AC 125 V / 250 V, 15 A
 DC 125 V, 0.4 A for resistance load
 DC 125V, 0.03 A for inductive load
 | 
| Conduit connection | ¾" PF (F) | 
| Process connection | ⅜", ½" PT, NPT and PF | 
| Certificates | KCS Ex d IIB+H2 T6 | 
| Hersteller |  |