Nominal diameter |
50 mm (2") |
Switch point accuracy |
±2.0 % of full scale |
Scale range |
0 ~ 28 MPa |
Working pressure |
Steady pressure : 75 % of full scale value Fluctuating pressure : 67 % of full scale value |
Working temperature |
Ambient : -20 ~ 65 °C Fluid : Max. 100 °C |
Temperature effect |
Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately ±0.4 % per 10 ℃ of full scale |
Pressure connection |
Type 316L SS electropolished low mount or center back mount surface finish Ra≤0.25 ㎛ ■ ¼" NPT male thread ■ VCR® male or female face seal fitting |
Element |
Type 316L SS <6 MPa : C-type bourdon tube ≥6 MPa : Helical type bourdon tube |
Case |
Type 304SS, Electropolished with pressure relief |
Cover and window |
Twist-lock polycarbonate |
Movement |
Stainless steel |
Pointer |
Black painted aluminium alloy |
Dial |
White PVC, with pointer stop pin With black/red lettering, dual pressure scale (bar) |
Helium leak rate |
Tested to confirm leakage rates of less than 10 -9 mbar • ℓ/sec</td |
Connection |
26 AWG, PVC 6 feet (2 m) |
Maximum switching current |
0.5 amps AC/DC noninductive load |
Maximum power |
10 W/DC, 12 VA/AC |
Maximum switching voltage |
28 V AC/DC |
Hersteller |
 |