These transmitters are recommended be used in the situation where the application of RTD signals to carry to a long distance or to guard against the heavy electrical field noise. The transmitters convert RTD inputs to an analog signal for a direct interface with indicators, recorders, controllers, PLC, DCS systems, and these can be used for a wide range of applications in process control, automatic machinery and hydraulic or pneumatic system design.
| Advantages | ■ Two wire 4 - 20 mA current output signal ■ RTD input
 ■ Measuring range from -50 ~ 400 ℃
 ■ Fixed range
 ■ Excellent accuracy and long term stability
 ■ Low - cost
 ■ Miniature design
 | 
| Electrical specification | Excitation voltage : 18 ~ 30 V Load resistance : Max. 500 Ω at 24 V
 Influence of excitation : 0.01 % FSO/V
 Burnout : Upscale (Approx. 23 mA DC) or Down scale (Approx. 4 mA DC)
 Reverse polarity : Protected
 Shock resistance : No change in performance after 10Gs for 11ms
 Vibration : 5g (10 ~ 2,000 Hz)
 Response time (10 ~ 90 %) : ±0.5 seconds
 Adjustment range : ±15 % of full scale / Zero and span
 | 
| Performance specification | Accuracy : ±0.2 % of full scale Non - linearity : Better than 0.10 % of full scale
 Repeatability : Better than 0.05 % of full scale
 Long term stability : Better than 0.05 % of full scale per month
 Ambient temperature limits : -20 ~ 70 ℃
 Ambient humidity limits : 5 ~ 95 % R.H
 | 
| Input | Measuring element : Pt 100 Ω at 0 ℃ | 
| Output | Current output Electrical connection type : 2-wire technique
 Full scale output signal : 20 mA ±0.2 %
 Zero measured output : 4 mA ±0.03 %
 Other output signals available on request
 | 
| Certificates | KCS Ex d IIC T6 | 
| Hersteller |  | 
Datenblatt: 
            Alle Funktionen und technischen Daten können ohne Ankündigung geändert werden, Lieferung vorbehaltlich Verfügbarkeit,Korrektur von Irrtümern und Auslassungen vorbehalten.